Fire-rated product line
Fire Rated Steel Doors
Steel fire doors and frames for export projects. UL certificates cover one model, KYFD001S: a single-swing, steel-covered composite door for masonry walls, rated up to and including 3 hours. Pairs, glazing, other walls and other sizes are confirmed per project, before production.
UL certificates: model KYFD001S only
Certificate facts
- UL 10B · model KYFD001S
- Up to 3 hours · masonry wall
- Single-swing, steel-covered composite door
- Every other rating confirmed per project

Model KYFD001S: what the UL certificates cover
Model KYFD001S is a single-swing, steel-covered composite fire door for openings in masonry walls, rated up to and including 3 hours. It is covered by UL Certificate of Compliance R41930 (Report Reference R41930-20251222, issued 25 December 2025) to UL 10B and CAN/ULC 104:2015 (R2025). Holder: Guangdong Jieyue Technology Co., Ltd.
| Model | KYFD001S |
|---|---|
| Door | Single-swing, steel-covered composite door |
| Rating | Up to and including 3 hours |
| Wall | Masonry construction |
| Product category | Swinging-type fire doors |
| Standards | UL 10B; CAN/ULC 104:2015 (R2025) |
| Certificate | UL Certificate of Compliance R41930, Report Reference R41930-20251222, issued 25 Dec 2025 |
| Expiry | No expiry date is printed. Current status is shown in UL Product iQ. |
| Holder | Guangdong Jieyue Technology Co., Ltd. |
Not covered by these certificates
- Pairs and double-egress doors
- Door frames (the certificate covers the door leaf)
- Lightweight or gypsum partitions
- Any model other than KYFD001S
- Vision panels, louvres, transoms and sidelights
- Maximum door size — not stated on the certificate
- Temperature-rise and smoke (S-label) ratings — not stated
- Hinges, locks, closers and other hardware — not listed on the certificate
Check it yourself: search UL Product iQ for Guangdong Jieyue Technology. For a matching project, we send the certificate copy on request.
Specifications
Rows marked "Not stated on the certificate" are outside what the certificate covers. For those items we confirm the construction for your opening before production.
Fire performance (certificate text)
| Model | KYFD001S |
|---|---|
| Door type | Single-swing, steel-covered composite door |
| Fire rating | Openings up to and including 3 hours |
| Wall | Masonry construction |
| Test standards | UL 10B; CAN/ULC 104:2015 (R2025) |
| Temperature rise | Not stated on the certificate |
| Smoke and draft (S label) | Not stated on the certificate |
| Certificate | UL Certificate of Compliance R41930 |
Door leaf
| Leaf thickness | 00 mm |
|---|---|
| Face sheets | Steel grade and sheet thickness, 0.0 mm |
| Core | Composite (as stated on the certificate). Core material: core material and density |
| Edges and reinforcement | Edge profile, and reinforcement at hinges and lock |
| Maximum leaf size covered by the certificate | As printed in UL Product iQ |
| Sizes made to order | Leaf sizes from 000 × 0000 mm to 0000 × 0000 mm. A size outside the certificate's scope is not covered by the certificate. |
| Handing | Left or right hand, inswing or outswing |
| Weight | 00 kg/m² |
Frame, hardware and glazing
| Frame | Not covered by the certificates (door leaf only). Frame type and steel thickness: frame profile and 0.0 mm steel |
|---|---|
| Hardware | Not listed on the certificate. Hardware set confirmed per project: hinges, lockset and closer of the usual set |
| Vision panel | Not stated on the certificate — confirmed per project |
| Louvre | Not stated on the certificate — confirmed per project |
Finish and installation
| Finish | Coating type and standard colours, to be confirmed |
|---|---|
| Installation | Masonry walls. Minimum wall thickness: 000 mm |
Frames and installation
A fire test burns the leaf, frame, hardware and seals together, fixed into one kind of wall. For KYFD001S, that wall is masonry. Our UL certificates cover the KYFD001S door leaf in masonry walls. Frames, hardware and seals are confirmed per project against your drawings and the evidence your authority accepts.
Installation
- Wall type covered: masonry construction
- Minimum wall thickness: 000 mm, per factory drawing
- Lightweight or gypsum partitions: not covered by the certificates
- Any other wall type: confirmed per project
- The wall itself must have at least the fire resistance the opening requires.
Frame
- Frame type: frame profile name and type
- Frame material and thickness: steel grade, 0.0 mm sheet
- Seal or gasket in the frame: seal type and position
- Fixing to the wall: anchor type and spacing for each wall type
- Joint between frame and wall: closed with a fire-rated material — sealant type, and who supplies it
- Door leaf
- Frame
- Hardware
- Seals
- Wall
Plan section through a door jamb. Schematic, not to scale; numbers match the list.
Transom
A glazed or solid panel above the door.
Sidelight
A glazed panel beside the door.
Borrowed light
A glazed frame in the wall, with no door.
Not covered by the KYFD001S certificates. Confirmed per project.
Other configurations, confirmed per project
The configurations below are not covered by the KYFD001S certificates. Tell us which ones your openings need. We confirm, opening by opening, what evidence applies — before production, never after delivery.
Pairs and unequal pairs
Double doors, including unequal-leaf pairs and double-egress pairs. The certificates cover single-swing doors only.
Confirmed per project
Vision panels
Glass in the door leaf. Not stated on the certificates; glass type and panel size are confirmed per project.
Confirmed per project
Louvres
Ventilation louvres in the door leaf. Not stated on the certificates.
Confirmed per project
Transoms and sidelights
Panels above or beside the door. The frame is outside the certificate scope.
Confirmed per project
Other wall types
Lightweight or gypsum partitions, and any wall other than masonry.
Confirmed per project
Larger or non-standard sizes
A size outside the certificate's scope is not covered by the certificate. Size covered by the certificate: to be read in Product iQ.
Confirmed per project
Temperature-rise doors
Doors that limit heat on the safe side, often specified for stairs. The certificates do not state a temperature-rise rating.
Confirmed per project
Smoke and draft control
S-label requirements are not stated on the certificates.
Confirmed per project
Added hardware
Panic bars, electric locks, viewers or kick plates: each item is checked against the certificate scope first.
Confirmed per project
Stainless steel faces
Stainless steel fire doors are not covered by the KYFD001S certificates; ratings are confirmed per project.
Confirmed per project
Need a size, glazing or pair that falls outside a tested construction? We tell you before production and offer three routes: change to a covered construction, a project assessment, or a new test priced into the quote.
Where steel fire doors are used
Stair and corridor openings, plant and service rooms, further locations the client confirms.
Building types taken from real projects, to be confirmed
A location on this list does not mean the door meets that building's special requirements. Temperature-rise ratings, often specified at stairs, and smoke ratings are not stated on the KYFD001S certificates.
Before you order
- Before ordering, confirm size, handing, frame and certificate scope with us.
- If an opening in your schedule falls outside a tested construction, we tell you before production.
- Cutting, drilling or adding hardware on site can take a door outside its tested construction. Ask us before you modify a door.
- A fire rating applies only to the construction that was tested, supplied and installed as specified.
- Any hardware or accessory added to the door, including holes cut on site, has to be confirmed against the certificate scope first.
Documents for KYFD001S
Certificate numbers and scope are public on this page. Copies go to buyers with a matching project — tell us the country, standard and openings first.
- UL Certificate of Compliance R41930 — UL 10B; CAN/ULC 104:2015 (R2025)On request
Straight answers
Are all your steel fire doors UL listed?
No. Our UL certificates cover one model, KYFD001S — a single-swing steel door for masonry walls, rated up to 3 hours. For other doors we confirm the rating and evidence per project, and tell you before production if an opening falls outside a tested construction.
Can I get a pair, or a door with a vision panel?
Pairs and doors with vision panels: our range to be confirmed. Neither is covered by the KYFD001S certificates, so we confirm the evidence for each such opening before you order.
Is a steel door fire rated by default?
No. A steel door is fire rated only when its construction has been tested and certified, and the leaf, frame, hardware and wall are installed as tested. A plain steel door is not a fire door.
Do you supply the frame with the door?
Frames supplied with the door: to be confirmed. The KYFD001S certificates cover the door leaf only, so the frame and its fixing are confirmed for each project.
Send your door schedule
For each steel door opening, tell us the rating, opening size, single leaf or pair, wall type, glazing or louvres, hardware and destination country. Send what you have — schedule, drawings or photos in PDF, Excel or Word — and mark what is still open.
We reply within N working days.